Building better barriers through flawless moisture detection

Posted: 28 Nov 2013 ?? ?Print Version ?Bookmark and Share

Keywords:National Renewable Energy Laboratory? moisture detection? film barrier? Electric Calcium Test?

One of the factors that result in the breakdown of cell phones, LED displays, TVs and solar photovoltaic (PV) panels is moisture. To retain product integrity, a transparent film barrier must work soundly to stand between moisture and the device itself. Now there is a test that can detect infinitesimally small amounts of moisture—and that can therefore give much greater assurance that the barrier films will last.

Developed by the Energy Department's National Renewable Energy Laboratory (NREL), the NREL Electric Calcium Test, or e-Ca, uses unique design elements to measure corrosion from water using calcium.

e-Ca glass card

NREL scientist Arrelaine Dameron works with an Electrical Calcium Test (e-Ca) glass card in a glovebox. The test measures water permeating through the thin-film barriers that guard cell phones, TVs, OLEDs and PV cells. (Credit: Dennis Schroeder).

Industry durability standards for PV modules call for tests lasting 1,000 hours in damp heat conditions. Module manufacturers want to be assured that any barriers they use will be able to pass the moisture-blocking test, so they can focus on optimizing the rest of the module. And they want to make sure that anything they buy has passed rigorous quality control.

The e-Ca method is 100 to 1,000 times more sensitive than other commercial tests designed to detect small amounts of moisture. NREL's test can detect down to 10 to the minus seven, or one ten-millionth of a gram of water per square meter per day. And it has 15 times greater throughput than the best commercial methods on the market today.

NREL's e-Ca method arrives at a time when the organic light-emitting diode (OLED) market is poised to explode—from $4.9 billion in 2012 for OLED displays to an expected $26 billion by 2018.

The method uses low-cost test cards with calcium metal traces that serve as moisture detectors. Any water vapor that passes through the barrier film reacts with the conductive calcium and forms resistive calcium hydroxide. It's that change in resistivity that yields the rate at which the water vapor permeates the film—the water vapor transmission rate, or WVTR.

The test cards are made in large batches in a moisture-free environment. When a barrier is ready to measure, it is sealed on one side of a metal donut-shaped 'spacer' element with the test card sealed to the other side. The whole assembly forms a small diffusion cell that can be tested in almost any environment. The spacer also serves as a convenient and reproducible means of adhering and controlling the flow of the edge seal that is used to seal the barrier to the test card, thus assuring that the barrier is the only thing being tested.

The assembly then attaches to custom NREL-assembled measurement electronics inside an environmental chamber that delivers a certain combination of heat and humidity. A good climate for testing is 45°C and 85 percent humidity, a condition hotter and wetter than even Bangkok, Thailand, on a miserable day. Testing in conditions beyond anything likely to be found in nature allows the test to be completed in less time. Another useful climate for testing is 85 percent humidity and 85°C, which is equivalent to 185°F and is a required reliability metric for PV manufacturing. Testing at 85°C ensures materials will be able to pass relevant qualification tests, and testing at 45°C gives permeation values relevant to the most severe climates in the world.

e-Ca assembly

The e-Ca assembly is composed of a test card, a spacer, the barrier film, an edge seal to seal the components together and a cable to connect the assembly to the measurement electronics. Module manufacturers want to be assured that any barriers they use will be able to pass the moisture-blocking test so they can focus on the rest of their module and they want to make sure that anything they buy has passed rigorous quality control. (Credit: Dennis Schroeder).

Five years ago, NREL scientists Arrelaine Dameron and Matthew Reese were both working on projects that required them to either make or research barriers. "We realized we didn't have the means to test in the sensitivity range we needed," said Dameron, who works in NREL's Chemical and Materials Science center.

NREL Senior Scientist Michael Kempe, who is part of NREL's PV Reliability group, joined them, and the trio started to devise a user-friendly test that could detect moisture in minuscule quantities.

"We started with a test method that had been reported in the literature, but we found that there were a number of ways we wanted to make it better," said Reese, who works at the NREL-based National Center for Photovoltaics.

So, the NREL team improved on the method in several key ways. Instead of depositing calcium directly on the barrier, they opted to deposit it on separate test cards. Instead of using one large, unpatterned calcium square, the test cards contain several maze-like ribbons of calcium, allowing both higher initial resistances for each trace (making it easier to measure) and redundancy built into every test card. They also inserted a calcium 'witness' sensor that monitors the integrity of the edge seal.